Stenner PumpsStenner 45 Series
Stenner 45 Series Pumps are manufactured in 120V and 220 Volt, 60Hz rated at 0 to 25 psi and 26 to 100 psi. Stenner pump come as a fixed head or adjustable. You may also purchase an optional tank with your Stenner Pump (orange). The product codes are: Pump Code (blue), the power type (purple), tube type (pink), and tube material (yellow)
Stenner Pump Part Number Breakdown for Model 45MJL-, 45MJH-, 45MFL-, and 45MFH-.
Optional Tank Number
| Model | Voltage & Hertz
| Suction & Discharge Tubing
| Tube Material
| S7G = 7.5 Gal, UV Gray
S7N = 7.5 Gal, White
S1G =15 Gal, UV Gray
S1N = 15 Gal, White
S3G = 30 Gal, UV Gray
S3N = 30 Gal, White
| 45MJL- 45MJH- 45MFL- 45MFH-
| A= 120V, 60Hz B= 220V, 60Hz
| 1= 1/4” White
2= 1/4” UV Black
3= 3/8” White
4= 3/8” UV Black
| S= Santoprene
T= Tygothane
|
Fixed Stenner Series 45 - 25 psi 45MFL1=3.0gpd 45MFL2=10.0gpd 45MFL3=22.0gpd 45MFL4=35.0gpd 45MFL5=50.0gpd
Fixed Stenner Series 45 - 100 psi 45MFH1=5.0gpd 45MFH2=10.0gpd 45MFH7=22.0gpd
Adjustable Stenner Series 45 - 25 psi 45MJL1=0.2-3.0gpd 45MJL2= 0.5-10.0gpd 45MJL3=1.1-22.0gpd 45MJL4 =1.7-35.0gpd 45MJL5 = 2.5-50.0gpd
Adjustable Stenner Series 45 - 100 psi 45MJH1=0.2-3.0gpd 45MJH2= 0.5-10.0gpd 45MJH7=1.1-22.0gpd
Stenner Series 85
Stenner Series 85 Single Head Adjustable and Fixed Pumps 0 to 25 psi and 26 to 100 psi, both come in 120 or 220 volt. You may also purchase an optional tank with your Stenner Pump (orange). The product codes are: Pump Code (blue), the power type (purple), tube type (pink), and tube material (yellow).
Stenner Pump Part Number Breakdown for Stenner Series 85: 85MJH-, 85MJL, 85MFL-, and 85MFH-:
Optional Tank Number
| Model | Voltage & Hertz
| Suction & Discharge Tubing
| Tube Material
| S7G = 7.5 Gal, UV Gray
S7N = 7.5 Gal, White
S1G =15 Gal, UV Gray
S1N = 15 Gal, White
S3G = 30 Gal, UV Gray
S3N = 30 Gal, White
| 85MJH- 85MJL- 85MFL- 85MFH-
| A= 120V, 60Hz B= 220V, 60Hz
| 1= 1/4” White
2= 1/4” UV Black
3= 3/8” White
4= 3/8” UV Black
| S= Santoprene
T= Tygothane
|
Adjustable Stenner Series 85 - 25 psi 85MJL1=0.3-5.0gpd 85MJL2=0.8-17.0gpd 85MJL3=2.0-40.0gpd 85MJL4=3.0-60.0gpd 85MJL5=4.3-85.0gpd
Adjustable Stenner Series 85 - 100 psi 85MJH1=0.3-5.0gpd 85MJH2=0.8-17.0gpd 85MJH7=2.0-40.0gpd
Fixed Stenner Series 85 - 25 psi
85MFL1=5.0gpd 85MFL2=17.0gpd 85MFL3=40.0gpd 85MFL4=60.0gpd 85MFL5=85.0gpd
Fixed Stenner Series 85 - 100 psi
85MFH1=5.0gpd 85MFH2=17.0gpd 85MFH7=40.0gpd
Stenner Series 100
Stenner Series 100 Fixed and Adjustable Dual Head Pumps. It comes in 120
and 220 Volt, 60Hz rated at 0 to 25 psi and 26 to 100 psi. The product
codes are: Pump Code (blue), the power type (purple), tube diameter
(pink), and tube material (yellow)
Stenner Pump Part Number Breakdown for Model 100FL-.
| Model | Voltage & Hertz
| Suction & Discharge Tubing
| Tube Material
| 100FL- 100FH- 100JL- 100JH-
| A= 120V, 60Hz B= 220V, 60Hz
| 1= 1/4” White
2= 1/4” UV Black
3= 3/8” White
4= 3/8” UV Black
| S= Santoprene
T= Tygothane
|
Fixed Dual Head Stenner Series 100FL - 25 psi 100FL1=6.0gpd 100FL2=20.0gpd 100FL3=44.0gpd 100FL4=70.0gpd 100FL5=100.0gpd
Fixed Dual Head Stenner Series 100FH - 100 psi 100FH1=6.0gpd 100FH2=20.0gpd
Adjustable Dual Head Stenner Series 100JL - 25 psi 100JL1=0.3-6.0gpd 100JL2=1.0-20.0gpd 100JL3=2.2-44.0gpd 100JL4=3.5-70.0gpd 100JL5=5.0-100.0gpd
Adjustable Dual Head Stenner Series 100JH - 100 psi 100JH1=0.3-6.0gpd 100JH2=1.0-20.0gpd
Stenner Series 170
Stenner Series 170 Fixed and Adjustable Dual Head Pumps. It comes in 120
and 220 Volt, 60Hz rated at 0 to 25 psi and 26 to 100 psi. The product
codes are: Pump Code (blue), the power type (purple), tube diameter
(pink), and tube material (yellow)
Stenner Pump Part Number Breakdown for Model 170FL-.
| Model | Voltage & Hertz
| Suction & Discharge Tubing
| Tube Material
| 170FL- 170FH- 170JL- 170JH-
| A= 120V, 60Hz B= 220V, 60Hz
| 1= 1/4” White
2= 1/4” UV Black
3= 3/8” White
4= 3/8” UV Black
| S= Santoprene
T= Tygothane
|
Adjustable Dual Head Stenner Series 170JL - 25 psi 170JL1=0.5-10.0gpd 170JL2=1.7-34.0gpd 170JL3=4.0-80.0gpd 170JL4=6.0-120.0gpd 170JL5=8.5-170.0gpd
Adjustable Dual Head Stenner Series 170JH - 100 psi 170JH1=0.5-10.0gpd 170JH2=1.7-34.0gpd
Fixed Dual Head Stenner Series 170FL - 25 psi 170FL1=10.0gpd 170FL2=34.0gpd 170FL3=80.0gpd 170FL4=1200.0gpd 170FL5=170.0gpd
Fixed Dual Head Stenner Series 170FH - 100 psi 170FH1=10.0gpd 170FH2=34.0gpd
Stenner PumpSeries SVP
The Manual SVP Series is a variable speed metering pump with a DC motor and detachable pump head. The SVP’s output is digitally adjusted to increase or decrease the motor speed.
The SVP1 pump is manually adjusted from 5%-100% in 1% increments with the up and down arrows on the keypad.
The SVP4 operates in a 4-20 mA mode with an external port to accept an input control signal. The SVP4 pump can override the 4-20mA mode to be manually adjusted.
Each may be ordered in 120 and 220 Volt, 60Hz rated at 0 to 25 psi and 26 to 100 psi. The product codes are: Pump Code (blue), the power type (purple), tube diameter (pink), and tube material (yellow)
Stenner Pump Part Number Breakdown for Model SVP-.
| Model | Voltage & Hertz
| Suction & Discharge Tubing
| Tube Material
| SPV1L- SPV4L- SPV1H- SPV4H-
| A= 120V, 60Hz B= 220V, 60Hz
| 1= 1/4” White
2= 1/4” UV Black
3= 3/8” White
4= 3/8” UV Black
| S= Santoprene
T= Tygothane
|
Manual Variable Speed SPV1L - 25 psi SVP1L1=0.3-5.0gpd SVP1L2=0.8-17.0gpd SVP1L3=2.0-40.0gpd SVP1L4=3.0-60.0gpd SVP1L5=4.3-80.0gpd
4 to 20 mAmp Variable Speed SPV4L - 25 psi SVP4L1=0.3-5.0gpd SVP4L2=0.8-17.0gpd SVP4L3=2.0-40.0gpd SVP4L4=3.0-60.0gpd SVP4L5=4.3-85.0gpd
Manual Variable Speed SPV1H - 100 psi SVP1H1=0.3-5.0gpd SVP1H2=0.8-17.0gpd SVP1H7=2.0-40.0gpd
4 to 20 mAmp Variable Speed SPV4H - 100 psi SVP4H1=0.3-5.0gpd SVP4H2=0.8-17.0gpd SVP4H3=2.0-40.0gpd SVP4H4=3.0-60.0gpd SVP4H5=4.3-85.0gpd
Stenner Proportional Injection System
The Stenner Proportional Injection System doses solution that is proportional to the system’s flow rate based on water volume. The water meter sends a signal to the PCM which actuates the pump. The system is suited for constant pressure (variable speed) well pumps, poultry and livestock houses, irrigation, systems with demand based backup wells and any application with varying flow rates.
The primary components are the PCM (pages 30 & 31), Classic Series single head fixed output pump (pages 2-7) and a 3/4" dry contact bronze water meter (page 33). The components are pre-assembled on a panel and include wall mounting brackets for quick installation and equipment accessibility. The cabinet keeps the cords and wires contained. Unions provide easy installation and removal. A flow indicator (page 44) is also installed as a visual reference to confirm solution is pumping. The Proportional Injection System is available as a Single or a Dual with two pumps, and two PCMs.
Stenner Pump Part Number Breakdown for Model BDF.
| Model | Pump Size | Pump & PCM Voltage
| PCM | Water Meter
| S = Single D = Dual
| 03= 3 gpd pump 05= 5 gpd pump 10 = 10 gpd pump 17 = 17 gpd pump 22 = 22 gpd pump 40 = 40 gpd pump
| 1= 120V, 60 Hz
| 01 = PCM1 05 = PCM5 10 = PCM10 20 = PCM20
| 751G = 3/4" 1 Gallons/Pulse 752P = 3/4" 2 Pulses/Gallon 752P = 3/4"4 Pulse/Gallon
|
PCM1 = 0.1-1.0sec PCM5 = 0.5-5.0sec PCM10 = 1.0-10.0sec PCM20 = 2.0-20.0 Note: Additional pulse rates available with two week lead time, contact factory.
BDF Series Series
The BDF Series metering pump is built with a low rpm motor and a detachable pump head. The pump has a fixed rpm motor which is activated by dip switches to inject scheduled daily doses of solution to a maximum of 21 ounces per event up to 25 psi. The BDF 24-hour pump can be programmed to activate hourly from 1 to 24 events per day. The BDF 7-day pump can be programmed to activate daily from 1 to 7 days per week.
The product codes are: Pump Code (blue), the power type (purple), tube diameter (pink), and tube material (yellow)
Stenner Pump Part Number Breakdown for Model BDF.
| Model | Voltage & Hertz
| Suction & Discharge Tubing
| Tube Material
| BDFHL- BDF7L- BDFHH- BDF7H-
| F=120V 60 Hz, USA 10' Cord
| 1= 1/4” White
| S= Santoprene
|
Manual Variable Speed BDFHL1 - 25 psi BDFHL1=0.06-1.3oz/hr BDFHL2=0.21-4.5oz/hr BDFHL3=0.48-10.0oz/hr BDFHL4=0.71-15.0oz/hr BDFHL5=1.0-21.0oz/hr
Manual Variable Speed BDF7L1 - 25 psi BDF7L1=0.06-1.3oz/hr BDF7L2=0.21-4.5oz/hr BBDF7L3=0.48-10.0oz/hr BDF7L4=0.71-15.0oz/hr BDF7L5=1.0-21.0oz/hr
Manual Variable Speed BDFHH - 100 psi BDFHH1=0.06-1.3oz/hr BDFHH2=1.30-4.50oz/hr
4 to 20 mAmp Variable Speed BDF7H - 100 psi BDF7H1=0.06-1.3oz/hr BDF7H2=0.21-4.5oz/hr
Tube_Material_Capability_Chart_Download.pdf
|